Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35.344
Filtrar
1.
PLoS One ; 19(4): e0299254, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38640136

RESUMO

Estuarine water quality is declining worldwide due to increased tourism, coastal development, and a changing climate. Although well-established methods are in place to monitor water quality, municipalities struggle to use the data to prioritize infrastructure for monitoring and repair and to determine sources of contamination when they occur. The objective of this study was to assess water quality and prioritize sources of contamination within Town Creek Estuary (TCE), Beaufort, North Carolina, by combining culture, molecular, and geographic information systems (GIS) data into a novel contamination source ranking system. Water samples were collected from TCE at ten locations on eight sampling dates in Fall 2021 (n = 80). Microbiological water quality was assessed using US Environmental Protection Agency (U.S. EPA) approved culture-based methods for fecal indicator bacteria (FIB), including analysis of total coliforms (TC), Escherichia coli (EC), and Enterococcus spp. (ENT). The quantitative microbial source tracking (qMST) human-associated fecal marker, HF183, was quantified using droplet digital PCR (ddPCR). This information was combined with environmental data and GIS information detailing proximal sewer, septic, and stormwater infrastructure to determine potential sources of fecal contamination in the estuary. Results indicated FIB concentrations were significantly and positively correlated with precipitation and increased throughout the estuary following rainfall events (p < 0.01). Sampling sites with FIB concentrations above the U.S. EPA threshold also had the highest percentages of aged, less durable piping materials. Using a novel ranking system combining concentrations of FIB, HF183, and sewer infrastructure data at each site, we found that the two sites nearest the most aged sewage infrastructure and stormwater outflows were found to have the highest levels of measurable fecal contamination. This case study supports the inclusion of both traditional water quality measurements and local infrastructure data to support the current need for municipalities to identify, prioritize, and remediate failing infrastructure.


Assuntos
Monitoramento Ambiental , Poluição da Água , Humanos , Idoso , Monitoramento Ambiental/métodos , Poluição da Água/análise , Cidades , North Carolina , Estuários , Bactérias/genética , Fezes/microbiologia , Microbiologia da Água
2.
Environ Sci Technol ; 58(15): 6540-6551, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38574283

RESUMO

Water age in drinking water systems is often used as a proxy for water quality but is rarely used as a direct input in assessing microbial risk. This study directly linked water ages in a premise plumbing system to concentrations of Legionella pneumophila via a growth model. In turn, the L. pneumophila concentrations were used for a quantitative microbial risk assessment to calculate the associated probabilities of infection (Pinf) and clinically severe illness (Pcsi) due to showering. Risk reductions achieved by purging devices, which reduce water age, were also quantified. The median annual Pinf exceeded the commonly used 1 in 10,000 (10-4) risk benchmark in all scenarios, but the median annual Pcsi was always 1-3 orders of magnitude below 10-4. The median annual Pcsi was lower in homes with two occupants (4.7 × 10-7) than with one occupant (7.5 × 10-7) due to more frequent use of water fixtures, which reduced water ages. The median annual Pcsi for homes with one occupant was reduced by 39-43% with scheduled purging 1-2 times per day. Smart purging devices, which purge only after a certain period of nonuse, maintained these lower annual Pcsi values while reducing additional water consumption by 45-62%.


Assuntos
Água Potável , Legionella pneumophila , Legionella , Abastecimento de Água , Microbiologia da Água , Engenharia Sanitária , Medição de Risco
3.
Sci Total Environ ; 927: 172190, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38575025

RESUMO

Identification of methods for the standardized assessment of bacterial pathogens and antimicrobial resistance (AMR) in environmental water can improve the quality of monitoring and data collected, support global surveillance efforts, and enhance the understanding of environmental water sources. We conducted a systematic review to assemble and synthesize available literature that identified methods for assessment of prevalence and abundance of bacterial fecal indicators and pathogens in water for the purposes of monitoring bacterial pathogens and AMR. After screening for quality, 175 unique publications were identified from 15 databases, and data were extracted for analysis. This review identifies the most common and robust methods, and media used to isolate target organisms from surface water sources, summarizes methodological trends, and recognizes knowledge gaps. The information presented in this review will be useful when establishing standardized methods for monitoring bacterial pathogens and AMR in water in the United States and globally.


Assuntos
Enterococcus , Monitoramento Ambiental , Escherichia coli , Salmonella , Microbiologia da Água , Enterococcus/isolamento & purificação , Salmonella/isolamento & purificação , Monitoramento Ambiental/métodos , Escherichia coli/isolamento & purificação
4.
Sci Total Environ ; 927: 172261, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38583611

RESUMO

The objective of this study was to comprehensively characterise the resistome, the collective set of antimicrobial resistance genes in a given environment, of two rivers, from their source to discharge into the sea, as these flow through areas of different land use. Our findings reveal significant differences in the riverine resistome composition in areas of different land uses, with increased abundance and diversity of AMR in downstream agricultural and urban locations, with the resistome in urban areas more similar to the resistome in wastewater. The changes in resistome were accompanied by changes in microbial communities, with a reduction in microbial diversity in downstream agricultural and urban affected areas, driven mostly by increased relative abundance in the phyla, Bacteroidetes and Proteobacteria. These results provide insight into how pollution associated with agricultural and urban activities affects microbial communities and influences AMR in aquatic water bodies. These results add valuable insights to form effective strategies for mitigating and preserving aquatic ecosystems. Overall, our study highlights the critical role of the environment in the development and dissemination of AMR and underscores the importance of adopting a One Health approach to address this global public health threat.


Assuntos
Agricultura , Rios , Rios/microbiologia , Agricultura/métodos , Monitoramento Ambiental , Microbiota/efeitos dos fármacos , Microbiologia da Água , Farmacorresistência Bacteriana/genética , Águas Residuárias/microbiologia , Bactérias/genética , Bactérias/efeitos dos fármacos
5.
J Water Health ; 22(3): 536-549, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38557569

RESUMO

Bacterial communities in drinking water provide a gauge to measure quality and confer insights into public health. In contrast to urban systems, water treatment in rural areas is not adequately monitored and could become a health risk. We performed 16S rRNA amplicon sequencing to analyze the microbiome present in the water treatment plants at two rural communities, one city, and the downstream water for human consumption in schools and reservoirs in the Andean highlands of Ecuador. We tested the effect of water treatment on the diversity and composition of bacterial communities. A set of physicochemical variables in the sampled water was evaluated and correlated with the structure of the observed bacterial communities. Predominant bacteria in the analyzed communities belonged to Proteobacteria and Actinobacteria. The Sphingobium genus, a chlorine resistance group, was particularly abundant. Of health concern in drinking water reservoirs were Fusobacteriaceae, Lachnospiraceae, and Ruminococcaceae; these families are associated with human and poultry fecal contamination. We propose the latter families as relevant biomarkers for establishing local standards for the monitoring of potable water systems in highlands of Ecuador. Our assessment of bacterial community composition in water systems in the Ecuadorian highlands provides a technical background to inform management decisions.


Assuntos
Água Potável , Humanos , Equador , RNA Ribossômico 16S/genética , Bactérias , Proteobactérias/genética , Microbiologia da Água
6.
J Water Health ; 22(3): 510-521, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38557567

RESUMO

Anecdotal evidence and available literature indicated that contaminated water played a major role in spreading the prolonged cholera epidemic in Malawi from 2022 to 2023. This study assessed drinking water quality in 17 cholera-affected Malawi districts from February to April 2023. Six hundred and thirty-three records were analysed. The median counts/100 ml for thermotolerant coliform was 98 (interquartile range (IQR): 4-100) and that for Escherichia coli was 0 (IQR: 0-9). The drinking water in all (except one) districts was contaminated by thermotolerant coliform, while six districts had their drinking water sources contaminated by E. coli. The percentage of contaminated drinking water sources was significantly higher in shallow unprotected wells (80.0% for E. coli and 95.0% for thermotolerant coliform) and in households (55.8% for E. coli and 86.0% for thermotolerant coliform). Logistic regression showed that household water has three times more risk of being contaminated by E. coli and two and a half times more risk of being contaminated by thermotolerant coliform compared to other water sources. This study demonstrated widespread contamination of drinking water sources during a cholera epidemic in Malawi, which may be the plausible reason for the protracted nature of the epidemic.


Assuntos
Cólera , Água Potável , Humanos , Abastecimento de Água , Cólera/epidemiologia , Estudos Transversais , Escherichia coli , Malaui/epidemiologia , Microbiologia da Água , Qualidade da Água
7.
World J Microbiol Biotechnol ; 40(6): 177, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656467

RESUMO

During the COVID-19 pandemic, the occurrence of carbapenem-resistant Klebsiella pneumoniae increased in human clinical settings worldwide. Impacted by this increase, international high-risk clones harboring carbapenemase-encoding genes have been circulating in different sources, including the environment. The blaKPC gene is the most commonly disseminated carbapenemase-encoding gene worldwide, whose transmission is carried out by different mobile genetic elements. In this study, blaKPC-2-positive Klebsiella pneumoniae complex strains were isolated from different anthropogenically affected aquatic ecosystems and characterized using phenotypic, molecular, and genomic methods. K. pneumoniae complex strains exhibited multidrug-resistant and extensively drug-resistant profiles, spotlighting the resistance to carbapenems, ceftazidime-avibactam, colistin, and tigecycline, which are recognized as last-line antimicrobial treatment options. Molecular analysis showed the presence of several antimicrobial resistance, virulence, and metal tolerance genes. In-depth analysis showed that the blaKPC-2 gene was associated with three different Tn4401 isoforms (i.e., Tn4401a, Tn4401b, and Tn4401i) and NTEKPC elements. Different plasmid replicons were detected and a conjugative IncN-pST15 plasmid harboring the blaKPC-2 gene associated with Tn4401i was highlighted. K. pneumoniae complex strains belonging to international high-risk (e.g., ST11 and ST340) and unusual clones (e.g., ST323, ST526, and ST4216) previously linked to clinical settings. In this context, some clones were reported for the first time in the environmental sector. Therefore, these findings evidence the occurrence of carbapenemase-producing K. pneumoniae complex strains in aquatic ecosystems and contribute to the monitoring of carbapenem resistance worldwide.


Assuntos
Antibacterianos , Variação Genética , Klebsiella pneumoniae , Testes de Sensibilidade Microbiana , Plasmídeos , beta-Lactamases , Klebsiella pneumoniae/genética , Klebsiella pneumoniae/isolamento & purificação , Klebsiella pneumoniae/efeitos dos fármacos , Klebsiella pneumoniae/enzimologia , beta-Lactamases/genética , beta-Lactamases/metabolismo , Antibacterianos/farmacologia , Plasmídeos/genética , Proteínas de Bactérias/genética , Proteínas de Bactérias/metabolismo , Farmacorresistência Bacteriana Múltipla/genética , Humanos , Infecções por Klebsiella/microbiologia , Ecossistema , Carbapenêmicos/farmacologia , Microbiologia da Água , Elementos de DNA Transponíveis
8.
Methods Mol Biol ; 2788: 397-410, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38656527

RESUMO

Early monitoring of Microcystis, a cyanobacterium that produces microcystin, is paramount in order to confirm the presence of Microcystis spp. Both phenotypic and genotypic methods have been used. The phenotypic methods provide the presence of the microcystis but do not confirm its species type and toxin produced. Additionally, phenotypic methods cannot differentiate toxigenic from non-toxigenic Microcystis. Therefore, the current protocol also describes genetic methods based on PCR to detect toxigenic Microcystis spp. based on microcystin synthetase E (mcy E) gene and 16-23S RNA genes for species-specific identification, which can effectively comprehend distinct lineages and discrimination of potential complexity of microcystin populations. The presence of these microcystin toxins in blood, in most cases, indicates contamination of drinking water by cyanobacteria. The methods presented herein are used to identify microcystin toxins in drinking water and blood.


Assuntos
Cianobactérias , Lagos , Microcistinas , Lagos/microbiologia , Microcistinas/genética , Microcistinas/análise , Cianobactérias/genética , Cianobactérias/isolamento & purificação , Fenótipo , Genótipo , Reação em Cadeia da Polimerase/métodos , Microbiologia da Água , Microcystis/genética , Microcystis/isolamento & purificação , Microcystis/classificação , Técnicas de Genotipagem/métodos
9.
Sci Total Environ ; 927: 172410, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38608884

RESUMO

There is little evidence of the long-term consequences of maintaining sanitary hot water at high temperatures on the persistence of Legionella in the plumbing system. The aims of this study were to describe the persistence and genotypic variability of L. pneumophila in a hospital building with two entirely independent hot water distribution systems, and to estimate the thermotolerance of the genotypic variants by studying the quantity of VBNC L. pneumophila. Eighty isolates from 55 water samples obtained between the years 2012-2017 were analyzed. All isolates correspond to L. pneumophila serogroup 6. The isolates were discriminated in four restriction patterns by pulsed-field gel electrophoresis. In one installation, pattern A + Aa predominated, accounting for 75.8 % of samples, while the other installation exhibited pattern B as the most frequent (81.8 % of samples; p < 0.001). The mean temperature of the isolates was: 52.6 °C (pattern A + Aa) and 55.0 °C (pattern B), being significantly different. Nine strains were selected as representative among patterns to study their thermotolerance by flow-cytometry after 24 h of thermic treatment. VBNC bacteria were detected in all samples. After thermic treatment at 50 °C, 52.0 % of bacteria had an intact membrane, and after 55 °C this percentage decreased to 23.1 %. Each pattern exhibited varying levels of thermotolerance. These findings indicate that the same hospital building can be colonized with different predominant types of Legionella if it has independent hot water installations. Maintaining a minimum temperature of 50 °C at distal points of the system would allow the survival of replicative L. pneumophila. However, the presence of Legionella in hospital water networks is underestimated if culture is considered as the standard method for Legionella detection, because VBNC do not grow on culture plates. This phenomenon can carry implications for the Legionella risk management plans in hospitals that adjust their control measures based on the microbiological surveillance of water.


Assuntos
Hospitais , Legionella pneumophila , Microbiologia da Água , Legionella pneumophila/isolamento & purificação , Legionella pneumophila/genética , Legionella pneumophila/fisiologia , Abastecimento de Água , Temperatura Alta
10.
Sci Total Environ ; 927: 172340, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38608909

RESUMO

Tackling the impact of missing data in water management is crucial to ensure the reliability of scientific research that informs decision-making processes in public health. The goal of this study is to ascertain the root causes associated with cyanobacteria proliferation under major missing data scenarios. For this purpose, a dynamic missing data management methodology is proposed using Bayesian Machine Learning for accurate surface water quality prediction of a river from Limia basin (Spain). The methodology used entails a sequence of analytical steps, starting with data pre-processing, followed by the selection of a reliable dynamic Bayesian missing value prediction system, leading finally to a supervised analysis of the behavioral patterns exhibited by cyanobacteria. For that, a total of 2,118,844 data points were used, with 205,316 (9.69 %) missing values identified. The machine learning testing showed the iterative structural expectation maximization (SEM) as the best performing algorithm, above the dynamic imputation (DI) and entropy-based dynamic imputation methods (EBDI), enhancing in some cases the accuracy of imputations by approximately 50 % in R2, RMSE, NRMSE, and logarithmic loss values. These findings can impact how data on water quality is being processed and studied, thus, opening the door for more reliable water management strategies that better inform public health decisions.


Assuntos
Teorema de Bayes , Cianobactérias , Monitoramento Ambiental , Aprendizado de Máquina , Qualidade da Água , Cianobactérias/crescimento & desenvolvimento , Monitoramento Ambiental/métodos , Espanha , Rios/microbiologia , Rios/química , Microbiologia da Água
11.
Sci Total Environ ; 927: 172257, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38608912

RESUMO

Waterborne pathogens threaten 2.2 billion people lacking access to safely managed drinking water services, causing over a million annual diarrheal deaths. Individuals without access to chlorine reagents or filtration devices often resort to do-it-yourself (DIY) methods, such as boiling or solar disinfection (SODIS). However, these methods are not simple to implement. In this study, we introduced an innovative and easily implemented disinfection approach. We discovered that immersing aluminum foil in various alkaline solutions produces alkali-treated aluminum foil (ATA foil) that effectively adsorbs Escherichia coli (E. coli), Salmonella, and Acinetobacter through the generated surface aluminum hydroxide. For example, a 25 cm2 ATA foil efficiently captures all 104E. coli DH5α strains in 100 mL water within 30 min. Using a saturated suspension of magnesium hydroxide, a type of fertilizer, as the alkaline solution, the properties of the saturated suspension eliminate the need for measuring reagents or changing solutions, making it easy for anyone to create ATA foil. ATA foils can be conveniently produced within mesh bags and placed in household water containers, reducing the risk of recontamination. Replacing the ATA foil with a foil improves the adsorption efficiency, and re-immersing the used foil in the production suspension restores its adsorption capacity. Consequently, ATA foil is an accessible and user-friendly alternative DIY method for underserved communities. Verification experiments covering variations in the water quality and climate are crucial for validating the efficacy of the foil. Fortunately, the ATA foil, with DIY characteristics similar to those of boiling and SODIS, is well-suited for testing under diverse global conditions, offering a promising solution for addressing waterborne pathogens worldwide.


Assuntos
Desinfecção , Água Potável , Purificação da Água , Água Potável/microbiologia , Água Potável/química , Desinfecção/métodos , Purificação da Água/métodos , Microbiologia da Água , Abastecimento de Água
12.
MMWR Surveill Summ ; 73(1): 1-23, 2024 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-38470836

RESUMO

Problem/Condition: Public health agencies in U.S. states, territories, and freely associated states investigate and voluntarily report waterborne disease outbreaks to CDC through the National Outbreak Reporting System (NORS). This report summarizes NORS drinking water outbreak epidemiologic, laboratory, and environmental data, including data for both public and private drinking water systems. The report presents outbreak-contributing factors (i.e., practices and factors that lead to outbreaks) and, for the first time, categorizes outbreaks as biofilm pathogen or enteric illness associated. Period Covered: 2015-2020. Description of System: CDC launched NORS in 2009 as a web-based platform into which public health departments voluntarily enter outbreak information. Through NORS, CDC collects reports of enteric disease outbreaks caused by bacterial, viral, parasitic, chemical, toxin, and unknown agents as well as foodborne and waterborne outbreaks of nonenteric disease. Data provided by NORS users, when known, for drinking water outbreaks include 1) the number of cases, hospitalizations, and deaths; 2) the etiologic agent (confirmed or suspected); 3) the implicated type of water system (e.g., community or individual or private); 4) the setting of exposure (e.g., hospital or health care facility; hotel, motel, lodge, or inn; or private residence); and 5) relevant epidemiologic and environmental data needed to describe the outbreak and characterize contributing factors. Results: During 2015-2020, public health officials from 28 states voluntarily reported 214 outbreaks associated with drinking water and 454 contributing factor types. The reported etiologies included 187 (87%) biofilm associated, 24 (11%) enteric illness associated, two (1%) unknown, and one (<1%) chemical or toxin. A total of 172 (80%) outbreaks were linked to water from public water systems, 22 (10%) to unknown water systems, 17 (8%) to individual or private systems, and two (0.9%) to other systems; one (0.5%) system type was not reported. Drinking water-associated outbreaks resulted in at least 2,140 cases of illness, 563 hospitalizations (26% of cases), and 88 deaths (4% of cases). Individual or private water systems were implicated in 944 (43%) cases, 52 (9%) hospitalizations, and 14 (16%) deaths.Enteric illness-associated pathogens were implicated in 1,299 (61%) of all illnesses, and 10 (2%) hospitalizations. No deaths were reported. Among these illnesses, three pathogens (norovirus, Shigella, and Campylobacter) or multiple etiologies including these pathogens resulted in 1,225 (94%) cases. The drinking water source was identified most often (n = 34; 7%) as the contributing factor in enteric disease outbreaks. When water source (e.g., groundwater) was known (n = 14), wells were identified in 13 (93%) of enteric disease outbreaks.Most biofilm-related outbreak reports implicated Legionella (n = 184; 98%); two nontuberculous mycobacteria (NTM) (1%) and one Pseudomonas (0.5%) outbreaks comprised the remaining. Legionella-associated outbreaks generally increased over the study period (14 in 2015, 31 in 2016, 30 in 2017, 34 in 2018, 33 in 2019, and 18 in 2020). The Legionella-associated outbreaks resulted in 786 (37%) of all illnesses, 544 (97%) hospitalizations, and 86 (98%) of all deaths. Legionella also was the outbreak etiology in 160 (92%) public water system outbreaks. Outbreak reports cited the premise or point of use location most frequently as the contributing factor for Legionella and other biofilm-associated pathogen outbreaks (n = 287; 63%). Legionella was reported to NORS in 2015 and 2019 as the cause of three outbreaks in private residences (2). Interpretation: The observed range of biofilm and enteric drinking water pathogen contributing factors illustrate the complexity of drinking water-related disease prevention and the need for water source-to-tap prevention strategies. Legionella-associated outbreaks have increased in number over time and were the leading cause of reported drinking water outbreaks, including hospitalizations and deaths. Enteric illness outbreaks primarily linked to wells represented approximately half the cases during this reporting period. This report enhances CDC efforts to estimate the U.S. illness and health care cost impacts of waterborne disease, which revealed that biofilm-related pathogens, NTM, and Legionella have emerged as the predominant causes of hospitalizations and deaths from waterborne- and drinking water-associated disease. Public Health Action: Public health departments, regulators, and drinking water partners can use these findings to identify emerging waterborne disease threats, guide outbreak response and prevention programs, and support drinking water regulatory efforts.


Assuntos
Água Potável , Legionella , Doenças Transmitidas pela Água , Humanos , Estados Unidos/epidemiologia , Microbiologia da Água , Surtos de Doenças , Abastecimento de Água , Vigilância da População
13.
PLoS One ; 19(3): e0297794, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38547180

RESUMO

This study assessed the physical, chemical, and microbiological quality with emphasis on risk score, source apportionment, geochemistry, feacal coliforms and water quality index of drinking water from selected water sources. A cross-sectional study was conducted in six villages in Mbarara city, south-western Uganda. Each selected source was inspected using a WHO-adopted sanitary inspection questionnaire. Each source's risk score was calculated. Thirty-seven samples were taken from one borehole, nine open dug wells, four rain harvest tanks, and twenty-three taps. The values for apparent color and phosphate were higher than the permissible level as set by the World Health Organization and Ugandan standards (US EAS 12). The isolated organisms were Klebsiella spp. (8.11%), Citrobacter divergens (62.16%), Citrobacter fluendii (2.7%), E. coli (35.14%), Enterobacter aerogenes (8.11%), Enterobacter agglomerus (5.4%), Proteus spp. (2.7%), Enterobacter cloacae (13.5%), and Proteus mirabilis (2.7%). Twelve water sources (32.4%) had water that was unfit for human consumption that was unfit for human consumption (Grade E), Five sources (13.5%) had water that had a very poor index (Grade D), nine (24.3%) had water of poor index (Grade C), eight (21.6%) had water of good water index (Grade B), and only three (8.1%) had water of excellent water quality index (Grade A). The piper trilinear revealed that the dominant water type of the area were Mgso4 and Caso4 type. Gibbs plot represents precipitation dominance. PCA for source apportionment showed that well, tap and borehole water account for the highest variations in the quality of drinking water. These results suggest that drinking water from sources in Mbarara city is not suitable for direct human consumption without treatment. We recommend necessary improvements in water treatment, distribution, and maintenance of all the available water sources in Mbarara City, South Western Uganda.


Assuntos
Água Potável , Abastecimento de Água , Humanos , Uganda , Escherichia coli , Estudos Transversais , Qualidade da Água , Microbiologia da Água
14.
Ann Agric Environ Med ; 31(1): 24-28, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38549473

RESUMO

INTRODUCTION: Legionella pneumophila is the primary etiological agent of Legionnaires' disease. These are opportunistic pathogens causing lung infections by inhalation of contaminated aerosols. Controlling the presence of these bacteria in domestic distribution water systems (mainly hot water systems) is important for reducing the threat they pose to human health. Legionella pathogens are detected and quantified during routine testing of water samples according to procedures included in PN-EN ISO 11731:2017. However, these procedures are labour-intensive, and the results are obtained after a relatively long time. Implementing the Legiolert™/Quanti-Tray® test as an alternative method may constitute a good solution: it simplifies the testing procedure and significantly reduces the time necessary to obtain the final result. OBJECTIVE: The aim of the study was to compare the relative recovery of Legionella from water samples tested according to PN-EN ISO 11731:2017, and the alternative method of the most probable number (MPN) with the Legiolert™/Quanti-Tray® (IDEXX) test, and to assess the suitability of the alternative method for routine testing. MATERIAL AND METHODS: Parallel testing was conducted of 38 hot water samples to detect and determine Legionella acc. to PN-EN ISO 11731:2017 and the Legiolert™/Quanti-Tray® test. Statistical analysis of the results was performed according to PN-EN ISO 17994:2014 and the McNemar's test. RESULTS: The Legiolert™ test was confirmed to be comparable in performance to the reference standardized method in both qualitative and quantitative detection of L. pneumophila in hot water samples. CONCLUSIONS: The study confirmed that the Legiolert™ test is specific and easy to use, and may constitute an alternative to standardized procedures used in the quantification of L. pneumophila in water.


Assuntos
Água Potável , Legionella pneumophila , Legionella , Doença dos Legionários , Humanos , Microbiologia da Água , Aerossóis e Gotículas Respiratórios , Doença dos Legionários/diagnóstico , Doença dos Legionários/microbiologia
15.
Environ Sci Technol ; 58(14): 6335-6348, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38530925

RESUMO

Fecal bacteria in surface water may indicate threats to human health. Our hypothesis is that village settlements in tropical rural areas are major hotspots of fecal contamination because of the number of domestic animals usually roaming in the alleys and the lack of fecal matter treatment before entering the river network. By jointly monitoring the dynamics of Escherichia coli and of seven stanol compounds during four flood events (July-August 2016) at the outlet of a ditch draining sewage and surface runoff out of a village of Northern Lao PDR, our objectives were (1) to assess the range of E. coli concentration in the surface runoff washing off from a village settlement and (2) to identify the major contributory sources of fecal contamination using stanol compounds during flood events. E. coli pulses ranged from 4.7 × 104 to 3.2 × 106 most probable number (MPN) 100 mL-1, with particle-attached E. coli ranging from 83 to 100%. Major contributory feces sources were chickens and humans (about 66 and 29%, respectively), with the highest percentage switching from the human pole to the chicken pole during flood events. Concentrations indicate a severe fecal contamination of surface water during flood events and suggest that villages may be considered as major hotspots of fecal contamination pulses into the river network and thus as point sources in hydrological models.


Assuntos
Monitoramento Ambiental , Escherichia coli , Humanos , Animais , Microbiologia da Água , Galinhas , Poluição da Água , Água , Fezes
16.
Sci Total Environ ; 926: 171389, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38432386

RESUMO

This research investigated the in-situ decay rates of four human wastewater-associated markers (Bacteroides HF183 (HF183), Lachnospiraceae Lachno3 (Lachno3), cross-assembling phage (crAssphage), pepper mild mottle virus (PMMoV) and three enteric viruses (human adenovirus 40/41 (HAdV 40/41), enterovirus (EV) and human norovirus GII (HNoV GII) in two estuarine water environments (Davidson Park (DP) and Hen and Chicken Bay (HCB) in temperate Sydney, NSW, Australia, employing qPCR and RT-qPCR assays. The study also aimed to compare decay rates observed in mesocosms with previously published laboratory microcosms, providing insights into the persistence of markers and viruses in estuarine environments. Results indicated varying decay rates between DP and HCB mesocosms, with HF183 exhibiting relatively faster decay rates compared to other markers and enteric viruses in sunlight and dark mesocosms. In DP mesocosms, HF183 decayed the fastest, contrasting with PMMoV, which exhibited the slowest. Sunlight induced higher decay rates for all markers and viruses in DP mesocosms. In HCB sunlight mesocosms, HF183 nucleic acid decayed most rapidly compared to other markers and enteric viruses. In dark mesocosms, crAssphage showed the fastest decay, while PMMoV decayed at the slowest rate in both sunlight and dark mesocosms. Comparisons with laboratory microcosms revealed faster decay of markers and enteric viruses in laboratory microcosms than the mesocosms, except for crAssphage and HAdV 40/41 in dark, and PMMoV in sunlight mesocosms. The study concludes that decay rates of markers and enteric viruses vary between estuarine mesocosms, emphasizing the impact of sunlight exposure, which was potentially influenced by the elevated turbidity at HCB estuarine waters. The generated decay rates contribute valuable insights for establishing site-specific risk-based thresholds of human wastewater-associated markers.


Assuntos
Bacteriófagos , Enterovirus , Tobamovirus , Vírus , Humanos , Animais , Feminino , Águas Residuárias , Monitoramento Ambiental , Galinhas , Austrália , Microbiologia da Água , Fezes
17.
J Occup Environ Hyg ; 21(4): 259-269, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38447033

RESUMO

Legionella pneumophila, the leading cause of Legionnaires' disease in the United States, is found in lakes, ponds, and streams but poses a health risk when it grows in building water systems. The growth of L. pneumophila in hot water systems of healthcare facilities poses a significant risk to patients, staff, and visitors. Hospitals and long-term care facilities account for 76% of reported Legionnaires' disease cases with mortality rates of 25%. Controlling L. pneumophila growth in hot water systems serving healthcare and hospitality buildings is currently achieved primarily by adding oxidizing chemical disinfectants. Chemical oxidants generate disinfection byproducts and can accelerate corrosion of premise plumbing materials and equipment. Alternative control methods that do not generate hazardous disinfection byproducts or accelerate corrosion are needed. L. pneumophila is an obligate aerobe that cannot sustain cellular respiration, amplify, or remain culturable when dissolved oxygen (DO) concentrations are too low (< 0.3 mg/L). An alternative method of controlling L. pneumophila growth by reducing DO levels in a hot water model system using a gas transfer membrane contactor was evaluated. A hot water model system was constructed and inoculated with L. pneumophila at DO concentrations above 0.5 mg/L. Once the model system was colonized, DO levels were incrementally reduced. Water samples were collected each week to evaluate the effect of reducing dissolved oxygen levels when all other conditions favored Legionella amplification. At DO concentrations below 0.3 mg/L, L. pneumophila concentrations were reduced by 1-log over 7 days. Under conditions in the hot water model system, at favorable temperatures and with no residual chlorine disinfectant, L. pneumophila concentrations were reduced by 1-log, indicating growth inhibition by reducing DO levels as the sole control measure. In sections of the model system where DO levels were not lowered L. pneumophila continued to grow. Reducing dissolved oxygen levels in hot water systems of healthcare and other large buildings to control L. pneumophila could also lower the risk of supplemental chemical treatment methods currently in use.


Assuntos
Desinfetantes , Legionella pneumophila , Legionella , Doença dos Legionários , Humanos , Doença dos Legionários/prevenção & controle , Abastecimento de Água , Engenharia Sanitária , Desinfetantes/farmacologia , Água/farmacologia , Microbiologia da Água , Temperatura Alta
18.
Sci Total Environ ; 927: 172005, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38554969

RESUMO

Analysis of dissolved organic matter (DOM) composition and microbial characteristics is crucial for tracing the sources of rural black and odorous water bodies (BOWB). The aim of this study was to explore the DOM and microbial diversity and identify the primary environmental factors in BOWB from various pollution sources during different periods using EEMs-PARAFAC and Illumina sequencing. It was found that the physicochemical properties vary widely across different pollution types of BOWB, with higher overall content during the high-water period compared to the normal-water period. The types of dissolved organic matter in BOWB are Tyrosine proteins, Fulvic acid, Dissolved microbial metabolites, and Humic acid. During the normal-water period, DOM originates primarily from terrestrial sources in various water bodies. However, DOM affected by livestock and poultry waste and industrial effluents is influenced by both internal and external sources during periods of high water levels. In industrial waste-type BOWB, the biological sources of water are weak. Proteobacteria, Actinobacteria, Chloroflexi, Firmicutes were the dominant bacterial phyla. According to the redundancy analysis, pH (p = 0.047), Total nitrogen (TN) (p = 0.045), Organic carbon (OC) (p = 0.044), and Nickel (Ni) (p = 0.047) are the primary environmental factors influencing the composition of bacterial communities.


Assuntos
Bactérias , Monitoramento Ambiental , Bactérias/classificação , Microbiologia da Água , Microbiota , China , Odorantes/análise , Substâncias Húmicas/análise , Poluentes Químicos da Água/análise
19.
Sci Total Environ ; 927: 172112, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556005

RESUMO

The number of nontuberculous mycobacteria (NTM) lung disease cases is increasing in the United States (US). This respiratory disease is primarily caused by three NTM species: Mycobacterium avium, M. intracellulare, and M. abscessus. Since disease transmission could occur through water aerosolization, this study investigated these three species' occurrence (sporadic and persistent) in hot water samples collected from residences (n = 70) and office buildings (n = 30) across the US. A longitudinal survey design was used. Three quantitative Polymerase Chain Reaction (qPCR) assays were used to measure the mycobacterial species in the water samples. Additionally, the water's disinfectant residual was measured. A structure's age and square footage were evaluated to predict mycobacterial contamination. Also, the seasonal occurrence of each species was assessed by structure type. Residences had a 43 % (30/70), and office buildings had a 77 % (23/30) detection frequency of one or more Mycobacterium spp. in their hot water. The age of the structure influenced M. intracellulare detection frequency but not M. avium and M. abscessus. The structure's square footage affected M. avium and M. intracellulare detection frequency but not M. abscessus. In chlorinated water, M. intracellulare was detected 1.4× more often in office buildings' hot water than in chloraminated water. In chloraminated water, the Mycobacterium spp. were detected 2-2.5× more often in residences, while M. avium and M. abscessus were detected 1.5-2.3× more often in office buildings, compared to chlorinated water. Each Mycobacterium spp. had a different trend associated with the type of structure and disinfectant. Further research is needed to better understand NTM occurrence in the built environment to improve public health.


Assuntos
Desinfetantes , Microbiologia da Água , Desinfetantes/análise , Micobactérias não Tuberculosas , Mycobacterium , Monitoramento Ambiental/métodos , Estados Unidos
20.
J Microorg Control ; 29(1): 1-7, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38508757

RESUMO

The growth of acid-fast bacteria often hinders the detection of Legionella in water samples on agar plates by the plate culture method. We studied whether anti-tubercular agents inhibit acid-fast bacteria growth on agar plates. First, the antimicrobial activities of isoniazid, ethionamide, and ethambutol were evaluated against Mycobacterium and Legionella. We found that ethambutol at ≥ 100 µg/mL completely inhibited Mycobacterium growth, but ethambutol at 1,000 µg/mL did not inhibit Legionella growth. Next, the effect of ethambutol dissolved in acid buffer was examined. Cell suspensions of L. pneumophila and Mycobacterium spp. were mixed, and ethambutol-acid buffer was added. After 5 min, mixtures were inoculated on GVPC agar plates and incubated at 36℃ for 6 d. We found that ethambutol inhibited Mycobacterium growth on agar plates, but the Legionella colonies recovered. The effect of ethambutol was also significant in the evaluation using bathwaters. Comparing 1,302 bathwaters, the addition of ethambutol reduced the detection rate of acid-fast bacteria from 30.6% to 0% and increased the detection rate of Legionella from 7.1% to 7.5%. Ethambutol, which selectively inhibited acid-fast bacteria growth, enhanced the detection of Legionella on agar plates and will contribute to improving the accuracy of Legionella testing by the plate culture method.


Assuntos
Legionella , Etambutol/farmacologia , Ágar , Microbiologia da Água , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...